Why Luceco Is the Lighting Brand Trade Buyers Keep Coming Back To

Wrong colour temperature, wrong IP rating, wrong driver compatibility — every one of those is a day lost on a commercial fit-out. Luceco takes most of that risk off the table.

Luceco Group | LinkedIn

Quick Answer

Luceco is a UK trade LED manufacturer covering panels, battens, strip lighting and emergency fittings. All BS EN 60598 compliant. Trade prices from £8 (5ft batten) to £45 (600x600mm panel). In stock at Kent Traders with same-day dispatch.

Browse Luceco at Trade Prices →

What Luceco Actually Makes

Five categories that trade buyers care about — and nothing that does not earn its place:

  • LED panels (600x600mm and 1200x300mm) — offices, retail, hospitality back-of-house, education
  • LED battens (2ft to 6ft) — warehouses, plant rooms, car parks, storerooms
  • LED strip and drivers — display lighting, under-cabinet runs, cove and feature work
  • Emergency lighting — maintained and non-maintained, 3-hour backup, BS EN 60598-2-22 tested
  • Outdoor fittings — PIR floodlights, bollard lights, IP65 wall lanterns

This is a trade-first range. Not a consumer brand moonlighting as a contractor supplier. The pricing, packaging and product construction are built for volume buyers.


Colour Temperature: The One Variable That Bites

More commercial specs go wrong on colour temperature than anything else. Once the fittings are in and the plasterer has been through, correcting a mismatch is a full strip-and-replace job at your cost.

Colour Temp Feel Right For
2700K Warm, amber Hotel guest rooms, restaurant dining, bedrooms
3000K Warm, clean Kitchens, bathrooms, hotel corridors and lobbies
4000K Cool, crisp Offices, schools, warehouses, plant rooms
6500K Daylight, blue-white Industrial, workshops, inspection areas

Hotel fit-out rule of thumb: 2700K or 3000K in all guest-facing areas, 4000K in back-of-house. Order one sample before committing to volume. Two days. Saves a week.


IP Ratings: Which Fitting Goes Where

Using the wrong IP rating in a wet or dusty location is a certification problem, not just a wear issue. Under BS 7671:2018 Regulation 701.512.3, bathroom Zone 1 requires IP45 minimum. Zone 2 requires IP44. No exceptions.

  • IP20 — dry indoor only. Standard office panel territory.
  • IP44 — splash-proof. Bathrooms outside Zone 1, kitchens, corridor entrances.
  • IP65 — dust-tight, jet-resistant. Commercial kitchens, car parks, loading bays, covered canopies.
  • IP66+ — full outdoor exposure. Luceco's floodlight and wall lantern range.
On catering kitchens specifically: An IP65 batten specified now is a much better long-term call than an IP44 that fails in two years when steam ingress catches up with the driver. The cost difference at order is small. The callback cost is not.

Luceco vs. The Competition

vs. Philips: Philips wins on brand recognition with end clients. Luceco wins on trade price — typically 20–30% cheaper for equivalent output and IP rating. If the client is not scrutinising the label on the fitting, Luceco is the call.

vs. Aurora: Closest competitor by market position. Luceco edges Aurora on driver reliability and IP65 batten strength. Aurora has more decorative residential options where Luceco's portfolio is lighter.

vs. Knightsbridge: Knightsbridge's lighting range is narrower and priced higher. For commercial panel and batten volume, Luceco covers more use cases at a better trade price.

Ordering for a multi-room or multi-property project? Kent Traders holds full Luceco stock. Volume pricing from 10 units per SKU. Phased delivery available. Project quotes in under 24 hours.

Get a Project Quote →

Frequently Asked Questions

Selected models include DALI-compatible drivers — not the full range. Check the spec sheet before ordering. Standard models use fixed-output drivers. If your BMS requires DALI, confirm driver type at quote stage.
Ra>80 on standard commercial models — meets CIBSE LG7 for general office and commercial use. Ra>90 available on selected lines for retail, medical and colour-critical applications, at around 15–25% price premium.
Yes — specify the IP65 batten. It protects against steam and directed water jets, covering a standard daily commercial kitchen cleaning regime. For walk-in cold rooms or high-pressure wash-down zones, confirm the IP spec before ordering.
Self-test models run a 30-second function test monthly and a full 3-hour duration test annually — automatically, no manual intervention needed. Results stored in the fitting's internal log. A red LED indicator flags any failed test.
Yes, at marked cut points only (typically every 50mm or 100mm depending on model). Cutting between marked points damages the circuit. Always pair with a Luceco driver rated for the total wattage of the run — not a generic driver from another brand.

Ready to Order Luceco?

In stock across panels, battens and emergency fittings. Same-day dispatch before 3pm. Trade accounts verified in one working day.

Browse Luceco at Kent Traders →
Previous articleScrewless Flat Plate Switches: The Upgrade Your Walls Have Been Waiting For All articles Next articleCorby of Windsor Hotel Kettles: Trade Buying Guide | Kent Traders

RELATED ARTICLES

Hotel LUGGAGE Racks
Hotel Luggage Racks: With Back or Without, Metal or Wood?

Hotel luggage racks come with or without a raised back, in metal or wood, and the choice shows up on your walls. This guide...

Basin Mixer or Pillar taps
Basin Mixer or Pillar Taps: Which Suits Your Basin?

Basin mixer or pillar taps? The basin decides it first, because pillar taps need two tap holes and a mono mixer needs one. This...

Bath Shower Mixer Tapes
Bath Shower Mixer Taps: Do They Work on Combi or Gravity?

A bath shower mixer tap looks like a simple swap, but whether it works depends on pressure and flow, not the boiler badge. This...

WALL HUNG WC
Which Wall-Hung WC Frame Height Fits Your Wall?

Wall hung toilet frame height decides whether a pan fits under a window or needs a taller wall. This guide compares the Geberit Alpha...

UK hotel room power load
Hotel Room Power Load: Kettle, Hair Dryer and Iron on One Socket?

A hotel guest room puts a kettle, a hair dryer and sometimes an iron within reach of the same sockets, and a 13A socket...

Astroflame fire door hinge
Fire Door Hinge Pads and Lock Kits: What Needs Protecting

A fire door is tested as a complete assembly, so every hinge recess and lock mortice cut into the leaf has to be protected...

Fire stopping pipe penetration
Fire Stopping Pipe Penetrations in HMOs and Hotels

A pipe through a fire-separating wall or floor is a hole in the fire rating unless it is sealed properly. This guide explains fire...

coshh for carpet cleaning
COSHH for Carpet Cleaning Chemicals in Hotels and HMOs

Carpet cleaning looks harmless until an inspector asks for the paperwork. This guide sets out what COSHH expects for carpet cleaning chemicals in hotels...

Which Shower for your water system
Which Shower for Your Water System? Combi, Tank or Unvented

The same shower can feel superb in one house and weak in the next, and the water system is almost always the reason. This...

Legionaire's Disease
Legionella Flushing for Empty Hotel and HMO Rooms

Empty hotel rooms and HMO bedrooms are where stagnant water collects, and stagnant water is where Legionella bacteria can multiply. This guide sets out...

Hard Water Uk
Hard Water in Hotels: Why Limescale Kills Kettles and Irons

Hard water carries dissolved calcium and magnesium, and heat turns them into limescale on kettle elements, iron soleplates and shower heads. This plain-English guide...

Electric Shower
Electric Shower kW Guide: 8.5, 9.5 or 10.5kW Compared | KT

Which electric shower kW rating do you need? For most homes 9.5kW is the sensible default, but the right answer depends on flow, winter...

Intumescent  strip size
Intumescent Strip Size for Fire Doors: 10, 15 or 20mm? | KT

Which intumescent strip size does your fire door need? Most 30-minute doors take 15mm x 4mm and most 60-minute doors take 20mm x 4mm...

trickle vents
Trickle Vents and Part F: Sizes for Replacement Windows | KT

Do replacement windows need trickle vents? In England, Part F of the Building Regulations says yes in most cases. New vents must match the...

Astro window restrictors
Window Restrictors: The 100mm Rule for Hotels, HMOs | KT

Window restrictors limit how far a window opens, usually to no more than 100mm, so a child or vulnerable adult cannot fall out. HSE...

Part m threshold
Part M Door Thresholds: The 15mm Rule Explained Simply | KT

Approved Document M Volume 2 wants entrance thresholds level, and where a raised one cannot be avoided it caps the total height at 15mm....

Shop products from this guide

Shop the products in this guide

View all