A shower toilet is a mains-powered appliance, and that is the part buyers overlook. The shower toilet electrical supply decides where the unit can go and who must fit it. This guide covers bathroom zones, what three models on our site state, and a priced worked example. Prices were checked on 25 November 2026.
Yes, a shower toilet needs a mains supply as well as water. BS 7671 Section 701 sets zones and IPX4 limits for rooms with a bath or shower, and the SELECT guide to it does not name shower toilets. Follow the manufacturer's instructions for your exact model, use 30 mA RCD protection and a competent electrician.
- Does a shower toilet need a mains electrical supply?
- Which bathroom zones matter for a shower toilet?
- Where can the power connection go?
- What do our three shower toilets state about power?
- Worked example: a WC 1.0 m from the bath, four rooms
- Where shower toilet electrics go wrong
- Shower toilet electrical supply checklist before you order
- Frequently asked questions
Does a shower toilet need a mains electrical supply?
Yes. Geberit UK says both power and water connections are needed to install a shower toilet from its AquaClean range. Our shower toilets collection listed 3 products on 25 November 2026, from £1,896.08 to £8,783.91.
All three models list a warm air dryer, and the Tuma and Mera also list odour extraction. That makes the electrical design part of the purchase, not an afterthought for the first fix.
Which bathroom zones matter for a shower toilet?
BS 7671 Section 701 covers rooms containing a bath or shower. The SELECT pocket guide to Section 701 summarises the zones in BS 7671:2018+A2:2022, the 18th Edition, and the table below follows it.
| Zone | Extent | What the guide says |
|---|---|---|
| Zone 0 | Inside the bath tub or shower basin | Interior of the bath or basin only |
| Zone 1 | Up to 2.25 m high above the bath or basin; 1.20 m from the fixed outlet if there is no basin | Equipment needs at least IPX4 |
| Zone 2 | 0.6 m horizontally beyond zone 1, up to 2.25 m | At least IPX4; SELV socket-outlets and switches, plus compliant shaver supply units |
| Outside the zones | The rest of the room | Other equipment allowed under the general rules, with 30 mA RCD protection |
The guide says nothing about shower toilets or bidets, and it says it does not cover every Section 701 requirement. It cannot tell you which zone a given model may sit in.
Where can the power connection go?
The manufacturer's data decides, and Section 701 sets the limit for the zone. Our Grohe Sensia Pro page lists IPX4 and a hidden power supply connection. IPX4 is the minimum rating the guide asks for in zones 1 and 2, but a rating alone does not make a location acceptable.
Sockets are the sticking point. The guide prohibits non-SELV socket-outlets within 2.5 m horizontally of the boundary of zone 1. Inside a small en-suite that rules out a plug-in supply, so a fixed connection is the likely route, subject to the model's manual.
Protection varies by manufacturer. The Grohe manual we read, for the Sensia Wall Hung rather than the Sensia Pro we list, asks for a high-sensitivity RCD rated 15 mA or below. The SELECT guide asks for 30 mA, so read the document for your exact model.
Section 701 is titled Locations containing a bath or shower, so its zones describe rooms with one. A WC-only cloakroom has neither, but BS 7671's general rules and the manufacturer's instructions still apply, so the design still needs a competent electrician.
What do our three shower toilets state about power?
Prices below are inc VAT as listed on 25 November 2026. The power column shows only what each product page states.
| Model | Price | What the page states on power |
|---|---|---|
| Grohe Sensia Pro 36508SH0 | £1,896.08 (was £2,747.94) | 220 to 240 V AC, 50 to 60 Hz, IPX4, hidden power supply connection, power switch. Wattage and fused spur not stated |
| Geberit AquaClean Tuma Comfort 146.310.11.1 | £2,861.14 (was £3,827.60) | Mains connection with flexible three-wire sheathed cable on the right. Voltage, rating and IP not stated |
| Geberit AquaClean Mera Comfort 146.210.11.1 | £8,783.91 | Warm air dryer and pre-heated seat listed. Supply, voltage and IP not stated |
All three ship direct from the supplier, usually within 3 to 5 working days. Where a page does not state voltage or IP rating, request the installation manual before you design the supply. Manufacturer installation guides differ between models on isolation and fusing.
Browse the wider toilets collection, 278 products on 25 November 2026, or pick a concealed frame from the installation frames collection, which listed 18 products with 12 in stock.
Worked example: a WC 1.0 m from the bath, four rooms
An operator fits four accessible en-suites. In each, the bath edge sits 1.0 m from the WC. Zone 2 ends 0.6 m beyond zone 1, so it stops 0.4 m short of the WC. Layouts vary, so check your own drawing.
| Check | Result in this layout |
|---|---|
| Bath edge to WC | 1.0 m |
| Zone 2 extent beyond zone 1 | 0.6 m, so it ends 0.4 m short of the WC |
| WC position | Outside the zones |
| Socket-outlet at the WC | Not allowed: it must be 2.5 m or more from zone 1 |
| Supply route | Fixed connection designed by a competent electrician |
| Model | Per unit | Four rooms |
|---|---|---|
| Grohe Sensia Pro 36508SH0 | £1,896.08 | £7,584.32 |
| Geberit AquaClean Tuma Comfort | £2,861.14 | £11,444.56 |
| Geberit AquaClean Mera Comfort | £8,783.91 | £35,135.64 |
The Sensia Pro costs £3,860.24 less than the Tuma across four rooms. These totals exclude frames, electrical work and labour, which we have not priced.
Where shower toilet electrics go wrong
- Treating IPX4 as permission. It is a minimum rating, not approval of the location.
- Quoting the socket distance from memory. The SELECT guide for the 18th Edition says 2.5 m, so check the current text.
- Planning a plug-in socket in an en-suite. Sockets are prohibited within 2.5 m of zone 1.
- Treating a cloakroom and an en-suite alike. Section 701 zones describe rooms with a bath or shower.
- Copying isolation from another model. Installation guides differ between models.
- Skipping 30 mA RCD protection. The guide asks for it on all low voltage circuits serving the room.
- Forgetting bonding on retrofits. For alterations, local supplementary bonding is needed unless three stated conditions are met.
Shower toilet electrical supply checklist before you order
Run this list before you order.
- Room type confirmed: bath or shower present, or WC-only.
- Zones marked on the drawing, including the 2.25 m height.
- Manufacturer's installation manual downloaded for the exact model.
- Voltage and IP rating taken from the manual, not guessed.
- Supply route agreed with a competent electrician before first fix.
- 30 mA RCD protection confirmed for the circuit.
- Supplementary bonding checked on retrofit rooms.
- Concealed frame and cistern matched to the model.
- Stock and dispatch time confirmed on the day you order.
Frequently asked questions
In practice, yes. The Grohe Sensia Wall Hung installation manual we read says all electrical installation must be carried out by a qualified electrician, and Section 701 sets zone and RCD rules for rooms with a bath or shower. Use a competent electrician to design and test the supply, and keep the manual with the job file.
Not in a room with a bath or shower if the socket sits within 2.5 m horizontally of zone 1. The SELECT guide to BS 7671 prohibits non-SELV socket-outlets within that distance. A WC-only cloakroom falls outside Section 701, but the manufacturer's instructions and an electrician's design still apply.
Zones 1 and 2 need equipment rated at least IPX4, according to the SELECT guide. Our Grohe Sensia Pro page lists IPX4, while the two Geberit pages do not state a rating, so request the installation manual. A rating alone does not approve a location, because Section 701 also limits which equipment may sit in each zone.
The SELECT guide says additional protection by 30 mA RCDs must be provided for all low voltage circuits serving a room with a bath or shower. A manufacturer may ask for different protection, so read both the guide and the model's manual, and let your electrician confirm the final arrangement.
Section 701 is titled Locations containing a bath or shower, and the SELECT guide covers rooms with one. A WC-only cloakroom has neither, so the zones do not map onto it. BS 7671's general rules and the manufacturer's instructions still apply, so ask a competent electrician to design the supply.
Each model has its own installation document, and isolation, fusing and connection type can differ. Our Tuma page lists a mains connection with flexible three-wire sheathed cable, while the Sensia Pro page lists a hidden power supply connection. Never copy an arrangement from another model's guide.
On 25 November 2026 our collection listed three models: the Grohe Sensia Pro at £1,896.08, the Geberit AquaClean Tuma Comfort at £2,861.14 and the Mera Comfort at £8,783.91. Prices exclude frames, electrical work and labour. The collection page showed two as low stock, and dispatch is direct from the supplier.
Related reading
Specify your shower toilet
Browse the shower toilets in stock, or apply for a trade account if you specify bathrooms regularly.