Quick answer

Fit a fixed head where a hose could reach a WC or bidet, because a fixed head has no hose to restrain. Choose a handset over a bath or tray, and keep its hose clear of the spill-over level or protect the supplies. Your water undertaker has the final say, so check before first fix.

20 mmAUK2 gap for a connection of 15 mm or less
30 mmAUK3 gap for a 15 mm connection
5.7 l/minflow limiter on our Grohe Tempesta 100 head

Fixed shower head vs handset: which should you fit?

Fit whichever the plumbing allows, then choose by use. A handset rinses the bath and aims easily. A fixed head frees a hand and sends no hose near the WC. Our handset shower heads collection listed 6 products from £30.54, and our fixed shower heads collection listed 5 from £44.66.

Stock is thin: 3 of the 6 handsets and 4 of the 5 fixed heads showed low stock, and the two Tempesta pages say dispatch is direct from the supplier, usually within 3 to 5 working days.

What does the hose rule say about a handset?

A handset on a hose that can reach into a toilet bowl or bidet is treated as fluid category 5, the highest backflow risk. Water Regs UK guidance says this applies in all premises, including a fixed head combined with a handset.

Unless the hose is permanently restrained or shortened to keep a Type AUK3 tap gap above the WC or bidet spill-over level, every supply to the shower needs fluid category 5 protection. Water Regs UK gives a break tank with a Type AB air gap as an example.

The legal anchor is Schedule 2 of the Water Supply (Water Fittings) Regulations 1999. Paragraph 15 asks for a backflow device suited to the highest fluid category that applies downstream. The Schedule does not name showers. The hose rule comes from guidance, which is informative rather than statutory, and the water undertaker decides the level.

Tap gap or check valves: how do you protect the bath or tray?

Over a bath or tray, the usual answer is a tap gap. The gap depends on the connection size and the fluid category, and it is measured to the spill-over level. Water Regs UK lists these minimums.

Type Connection Minimum gap
AUK2, fluid category 3 15 mm or less 20 mm
AUK2, fluid category 3 Over 15 mm, under 20 mm 25 mm
AUK2, fluid category 3 20 mm or larger 70 mm
AUK3, fluid category 5 15 mm 30 mm
AUK3, fluid category 5 20 mm 40 mm

For a fixed head, the gap runs from its lowest point to the spill-over level. If the gap cannot be kept, the supplies need other protection suited to the risk.

Valves help in two ways. Single check valves on the supplies to the shower valve generally cover cold water pressurising the hot supply, and hot water entering the cold mains under fault conditions. Double check valves on the supply also cover back siphonage through the hose, but only to fluid category 3.

Rule

A double check valve protects to fluid category 3 only. It cannot protect a hose that can reach a toilet bowl or bidet.

Which room suits a fixed head, a handset or a rail kit?

Start with what the hose could touch, then pick the outlet. Our shower rail kits collection listed 3 sets from £54.37, with one in stock and two on low stock.

Location Better fit Why
Room where the WC or bidet is within hose reach Fixed head No hose to restrain or shorten
Over-bath shower Handset on a rail Easy to rinse the bath, with the gap or double check valves protecting the supply
Shower tray with no WC or bidet in reach Either A handset still needs a gap above the tray
Low-pressure supply Check the head first Both Grohe Tempesta pages state a 1.0 bar minimum

What do our heads and handsets state?

Prices below are inc VAT as listed on 27 November 2026. The last column shows only what each product page states.

Product Price What the page states
Grohe Tempesta 110 Handshower 28261003 £30.54 (was £44.27), low stock on the collection page Rain, Jet and Massage sprays, SpeedClean anti-limescale, 1.0 bar minimum, brass body. Flow rate and hose not stated
Grohe New Tempesta 100 Fixed Shower Head 26050001 £44.66 (was £64.72), in stock 100 mm, 1 spray, 5.7 l/min flow limiter, SpeedClean, 1.0 bar minimum, 5-year guarantee. Arm not stated
Grohe Euphoria 110 Massage Rail Set 27231001 £101.87 (was £147.64), in stock 3 spray handset on a rail set. Hose and rail length not stated

Where a page states no flow rate or hose length, ask before you order, because hose length decides whether a handset can reach a WC.

Worked example: four bathrooms, two layouts

A landlord refits four bathrooms. Two en-suites have the WC within hose reach of the shower. Two family bathrooms have a bath and no WC nearby.

Room type Outlet Qty Cost
En-suites Grohe New Tempesta 100 fixed head 26050001 2 £89.32
Family bathrooms Grohe Euphoria 110 Massage Rail Set 27231001 2 £203.74
Total 4 £293.06

A rail kit in all four rooms would cost £407.48, so the mix costs £114.42 less and keeps two hoses away from the WC. Prices exclude valves, arms, check valves and labour. Over the baths, keep the hose gap or protect the supplies.

Where handset choices go wrong

  • Letting the hose reach the WC. A handset that can reach a bowl or bidet is fluid category 5.
  • Measuring the gap by eye. For a fixed head, measure from its lowest point to the spill-over level.
  • Skipping the pressure check. Both Grohe Tempesta pages state a 1.0 bar minimum.
  • Assuming the rules only cover new builds. If work is not notifiable, the owner or occupier is still responsible for compliance.

Fixed head or handset checklist before you order

Run this list before you order.

  • Hose reach checked against every WC and bidet in the room.
  • Fixed head chosen where a hose could reach a bowl.
  • Tap gap or check valves planned for the bath or tray.
  • Minimum pressure checked against your supply.
  • Flow rate and hose length taken from the product page or manual.
  • Water undertaker consulted on notification and backflow level.
  • Stock confirmed on the day you order.

Frequently asked questions

Neither wins outright. A fixed head has no hose, so it avoids the toilet-reach test and leaves a hand free. A handset rinses the bath or tray and aims easily, but its hose must keep a tap gap or have check valves. Choose by room layout first, then by how you wash.

Water Regs UK says a hose handset that can reach into a toilet bowl or bidet is a fluid category 5 risk in all premises. Unless the hose is permanently restrained or shortened to keep a Type AUK3 gap above the spill-over level, the supplies need fluid category 5 protection. Your water undertaker decides the final level.

Sometimes. For a fluid category 3 installation, double check valves on the supply to the shower valve also address back siphonage through the hose when the tap gap cannot be kept. They protect to category 3 only, so they cannot cover a hose that reaches a toilet or bidet.

For a Type AUK2 gap, Water Regs UK lists 20 mm for connections up to 15 mm, 25 mm above that and under 20 mm, and 70 mm for 20 mm or larger. For a fixed head, the gap runs from its lowest point to the spill-over level. Confirm the figure with your water undertaker.

It depends on the model. Our Grohe New Tempesta 100 page states a minimum recommended pressure of 1.0 bar and lists it as suitable for instantaneous heaters, and the Tempesta 110 handshower page also states 1.0 bar. Check your supply pressure before you buy, because a head rated above your pressure will disappoint.

A rail kit bundles the handset, hose and holder, so the parts are matched. On 27 November 2026 our shower rail kits collection listed three sets from £54.37. The pages we read did not state hose length, so confirm the hose reaches where you need it and no further.

Not exactly. Scotland uses water byelaws, and Northern Ireland has its own Water Fittings Regulations with their own notification rules, so details can differ from England and Wales. Check with your local water supplier before you design a hose arrangement.

Related reading

Choose your shower outlet

Browse handset shower heads in stock, or apply for a trade account if you specify bathrooms regularly.

Shop handset shower headsApply for a trade account

Previous articleShower Toilet Electrical Supply: What It Needs and Where It Goes All articles

RELATED ARTICLES

Shower Toilet Electrical Supply
Shower Toilet Electrical Supply: What It Needs and Where It Goes

A shower toilet needs mains power as well as water, and the supply decides where the unit can go and who must fit it....

How often Do fire doors needs checking
How Often Do Fire Doors Need Checking? The 8-Point Inspection

Fire door checks follow a fixed rhythm in England: communal doors every three months and flat entrance doors every twelve months, in buildings over...

How many bathrooms required by law in a workplace
How Many Toilets Does a Workplace Need by Law?

Workplace toilets have a legal minimum that follows peak headcount, not payroll. This guide sets out HSE’s tables for mixed-use and men-only toilets, the...

Slotted bs Unslotted basin waste
Slotted or Unslotted Basin Waste: Which Does Your Basin Need?

Slotted or unslotted basin waste comes down to one check: does the basin have an overflow? This guide shows how to check, compares the...

Sanitary bins in hotel bathrooms
Sanitary Bins in Hotel Bathrooms: What the Law Requires

Waste companies often call a sanitary bin a legal requirement in every hotel bathroom, but the picture is more precise than that. This guide...

Evac Chairs UK
Evacuation Chairs: Do You Need One and Which Model?

An evacuation chair is one way to get someone down a stair in a fire, but it is not the only way and the...

Hotel bedroom bins
Hotel Bedroom Bins: Does Each Room Need a Recycling Split?

England’s workplace recycling rules cover hotels, guest houses and short-term lets, but they do not say which bin goes in the bedroom. This guide...

Hotel LUGGAGE Racks
Hotel Luggage Racks: With Back or Without, Metal or Wood?

Hotel luggage racks come with or without a raised back, in metal or wood, and the choice shows up on your walls. This guide...

Basin Mixer or Pillar taps
Basin Mixer or Pillar Taps: Which Suits Your Basin?

Basin mixer or pillar taps? The basin decides it first, because pillar taps need two tap holes and a mono mixer needs one. This...

Bath Shower Mixer Tapes
Bath Shower Mixer Taps: Do They Work on Combi or Gravity?

A bath shower mixer tap looks like a simple swap, but whether it works depends on pressure and flow, not the boiler badge. This...

WALL HUNG WC
Which Wall-Hung WC Frame Height Fits Your Wall?

Wall hung toilet frame height decides whether a pan fits under a window or needs a taller wall. This guide compares the Geberit Alpha...

UK hotel room power load
Hotel Room Power Load: Kettle, Hair Dryer and Iron on One Socket?

A hotel guest room puts a kettle, a hair dryer and sometimes an iron within reach of the same sockets, and a 13A socket...

Astroflame fire door hinge
Fire Door Hinge Pads and Lock Kits: What Needs Protecting

A fire door is tested as a complete assembly, so every hinge recess and lock mortice cut into the leaf has to be protected...

Fire stopping pipe penetration
Fire Stopping Pipe Penetrations in HMOs and Hotels

A pipe through a fire-separating wall or floor is a hole in the fire rating unless it is sealed properly. This guide explains fire...

coshh for carpet cleaning
COSHH for Carpet Cleaning Chemicals in Hotels and HMOs

Carpet cleaning looks harmless until an inspector asks for the paperwork. This guide sets out what COSHH expects for carpet cleaning chemicals in hotels...

Which Shower for your water system
Which Shower for Your Water System? Combi, Tank or Unvented

The same shower can feel superb in one house and weak in the next, and the water system is almost always the reason. This...

Shop products from this guide